An experimental and numerical study on hydrodynamic characteristicsof horizontal annular type water-air ejector
Yoon Kee Kim, Dong Yeop Lee, Hyun Dong Kim, Joo Ha Ahn and Kyung Chun Kim*
The Journal of Mechanical Science and Technology, vol. 26, no. 9, pp.2773-2781, 2012
Abstract : A water-driven annular type ejector loop is designed and constructed for air absorption. Fabricated ejector unit is horizontally installed
in the loop, and annular water jet at the throat entrained atmospheric air through the circular pipe placed at the center of the ejector. The
tested range of water flow rate is 160 L/min to 320 L/min and volumetric flow rate of water and air and local pressure are quantitatively
measured using LabVIEW signal express program. For the quantitative measurement of bubble velocity, cinematic PIV technique using
a high speed camera is adapted. In post processing, each bubble is used as seeding particles and ensemble averaged bubble velocity field
at vertical plane of the ejector system is finally acquired. In the range of experiment, the bubble size distribution at downstream of the
ejector seems to be quite uniform so that the flow can be classified as a homogeneous bubbly flow. In case of low range of water flow
rate, the transition from bubbly flow to stratified flow occurs at the atmospheric outlet condition. As a comparative study, a numerical
simulation on the same ejector shape is performed to understand the more detail hydrodynamic characteristics in the annular type ejector
system. Homogeneous bubbly flow regime is used as default two-phase flow regime, and void fraction at the vertical plane of the ejector
system is qualitatively compared with that of experiment. In volume flow rate comparison, numerical prediction agrees well with that of
experiment where the homogeneous bubbly flow is maintained.
Keyword : Annular type ejector; Air entrainment; Particle image velocimetry; Computational fluid dynamics; Homogeneous bubbly flow |