Application of averaging bidirectional flow tube for measurement of single-phase flow rate in a piping system
Kyoung-Ho KANG
The Journal of Mechanical Science and Technology, vol. 23, no. 3, pp.758-767, 2009
Abstract : A new instrument, an averaging bidirectional flow tube (BDFT), is proposed to measure single-phase flow rates.
This averaging BDFT has unique measuring characteristics foremost among which is the capability to measure bidirectional
flow and insensitivity of the fluid attack angle. Single phase calibration tests were conducted to demonstrate
the performance of the averaging BDFT. Likewise, to enhance the applicability of the averaging BDFT on various flow
conditions, flow analyses using CFD code were performed focusing on design optimization of the BDFT. The calibration
test results indicated that this averaging BDFT has a linearity within 0.5 % in the Reynolds (Re) number range of
above 10,000 where it is meaningful in terms of application. The flow analyses results demonstrate a good linearity of
the averaging BDFT with various design features. Therefore, averaging BDFT can be applied for measurement of flow
rates within a wide range of flow conditions.
Keyword : Averaging bidirectional flow tube (BDFT); Calibration test; Flow analysis |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
JMST Editorial Office: #702 KSTC New Bldg, 22 7-gil, Teheran-ro, Gangnam-gu, Seoul 06130, Korea
TEL: +82-2-501-3605, E-mail: editorial@j-mst.org |
JMST Production Office: #702 KSTC New Bldg, 22 7-gil, Teheran-ro, Gangnam-gu, Seoul 06130, Korea
TEL: +82-2-501-6056, FAX: +82-2-501-3649, E-mail: editorial@j-mst.org |
|
|
|
|