Phase of acoustic impedance and performance of standing wave thermoacoustic coolers
Insu Paek
The Journal of Mechanical Science and Technology, vol. 23, no. 5, pp.1476-1484, 2009
Abstract : Investigations on the relations between the phase angle of the acoustic impedance at the driver piston and the system
performance of a standing wave thermoacoustic cooler were performed. The system performance measured at a fixed
acoustic power showed that the coefficient of performance of the standing wave thermoacoustic cooler increases as the
phase angle increases when the stack temperature span is relatively low. The results were consistent with the simulation
results obtained from DELTAE, a computer code based on linear thermoacoustic theory. Analysis on the temperature
profiles along the stack showed that the cooling efficiency (COP) of the system could be decreased or increased as the
phase angle of the acoustic impedance at the driver piston changes depending on the stack temperature spans.
Keyword : Coefficient of performance; Phase angle; Stack temperature span; Thermoacoustic cooler performance |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
JMST Editorial Office: #702 KSTC New Bldg, 22 7-gil, Teheran-ro, Gangnam-gu, Seoul 06130, Korea
TEL: +82-2-501-3605, E-mail: editorial@j-mst.org |
JMST Production Office: #702 KSTC New Bldg, 22 7-gil, Teheran-ro, Gangnam-gu, Seoul 06130, Korea
TEL: +82-2-501-6056, FAX: +82-2-501-3649, E-mail: editorial@j-mst.org |
|
|
|
|