Removal of submicron aerosol particles and bioaerosols using carbon fiber ionizer assisted fibrous medium filter media
Jae-Hong Park
The Journal of Mechanical Science and Technology, vol. 23, no. 7, pp.1846-1851, 2009
Abstract : This paper reports the installation of a carbon fiber ionizer in front of a fibrous medium filter to enhance the removal
of submicron aerosol particles and bioaerosols. Test particles (KCl) were classified with a size range of 50-600 nm
using a differential mobility analyzer (DMA). The number concentration of the test particles was measured using a
condensation particle counter (CPC). The average charge per particle was estimated by current measurements using an
aerosol electrometer. At the face velocity of 0.5 m/s, the particle removal efficiency was 31.4% (for dp=100 nm) when
the ionizers were not operating but increased to 35.7% and 46.9% at 1.6¡¿1011ions/s and 6.4¡¿1012ions/s with the ionizers,
respectively. For the antibacterial tests, the test bioaerosols (E. coli) were aerosolized using a nebulizer and were
deposited on the filter media for 5 minutes. After the deposited bioaerosols were exposed to unipolar air ions, they were
incubated for 12 hours. The survival efficiency of E. coli was measured using a colony counting method. The survival
fractions of E. coli exposed to positive air ions for 1, 5 and 10 minutes were 61.7%, 45.4% and 25.2%, respectively.
Keyword : Submicron aerosol particle; Bioaerosols; Particle charging; Fibrous medium |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|