Maximum suction lift of water jet pumps
Iran E. Lima Neto
The Journal of Mechanical Science and Technology, vol. 25, no. 2, pp.391-394, 2011
Abstract : This paper describes an experimental study on water jet pumps with different diameters and nozzle-to-throat area ratios. The results revealed
that the area ratio was an important parameter to characterize the maximum suction lift of the jet pumps, while their diameters had
a negligible effect. All jet pumps reached the cavitation regime at a suction lift of about 8 mH2O. In the non-cavitating region, it was
found that the higher the area ratio, the higher the maximum suction lift for the same motive pressure head. However, the lower the area
ratio, the higher the resistance to enter the cavitation regime. A dimensionless correlation was obtained for the non-cavitating region to
describe the maximum suction lift as a function of a modified Thoma number and the area ratio. Curve fitting of experimental data also
provided a dimensionless correlation to predict the onset of cavitation. Finally, applications of the results are presented.
Keyword : Cavitation; Ejector; Jet pump; Suction head; Water |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
JMST Editorial Office: #702 KSTC New Bldg, 22 7-gil, Teheran-ro, Gangnam-gu, Seoul 06130, Korea
TEL: +82-2-501-3605, E-mail: editorial@j-mst.org |
JMST Production Office: #702 KSTC New Bldg, 22 7-gil, Teheran-ro, Gangnam-gu, Seoul 06130, Korea
TEL: +82-2-501-6056, FAX: +82-2-501-3649, E-mail: editorial@j-mst.org |
|
|
|
|