Evaluation of gas path analysis methods for gas turbine diagnosis
A. G. Stamatis *
The Journal of Mechanical Science and Technology, vol. 25, no. 2, pp.469-477, 2011
Abstract : In the present paper, limitations concerning three implementations of gas path analysis (GPA) methods are investigated and their diagnostic
effectiveness is evaluated. The methods were tested for different sets of faults on a twin shaft gas turbine with an instrumentation
set typical of today¡¯s engines. Test results revealed that classical GPA is not sufficient. Correct diagnosis is provided only when one already
knows a subset of components containing the fault; otherwise, the fault may be attributed to other component (s). The effectiveness
of a second method that implements Multi Operating Point Analysis (MOPA) is related with the assumption of non varying health parameters
with deviations along with the operating point. Cases of wrong diagnosis were detected when the above assumption was violated.
Improvement on the diagnostic effectiveness of the MOPA method has been verified through careful selection of the parameters
defining the operating point. Further improvement on diagnostic ability was achieved when a third, recently proposed method was applied.
The method uses information produced from existing sensors when artificial operating points are defined close to the initial operating
point. It was found that the third method can detect and correctly identify faults even in cases where the multipoint method fails.
Keyword : Diagnostics; Gas path analysis; Gas turbine; Fault identification; Multipoint analysis |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
JMST Editorial Office: #702 KSTC New Bldg, 22 7-gil, Teheran-ro, Gangnam-gu, Seoul 06130, Korea
TEL: +82-2-501-3605, E-mail: editorial@j-mst.org |
JMST Production Office: #702 KSTC New Bldg, 22 7-gil, Teheran-ro, Gangnam-gu, Seoul 06130, Korea
TEL: +82-2-501-6056, FAX: +82-2-501-3649, E-mail: editorial@j-mst.org |
|
|
|
|