A numerical study on the unsteady flow behavior and the performance of an automotive sirocco fan Yohan Jung
The Journal of Mechanical Science and Technology, vol. 22, no. 10, pp.1889-1895, 2008
Abstract : An automotive sirocco fan has been widely used in air-conditioning devices. It is essential to understand the flow
characteristics of an automotive sirocco fan to satisfy the trends for more efficient and less noise. In this study, numerical
calculations were conducted to explain the three-dimensional unsteady, incompressible flow characteristics and
performance of the sirocco fan using FLUENT. Reynolds-averaged Navier-Stokes equations with the standard rd k −¥å
turbulence model were used for the numerical analysis. The sliding mesh was used to simulate the relative transient
motion of impeller against scroll. It was found that the inactive zone and the secondary flow reduce efficiency because
they cause internal losses. A parametric study was performed to improve efficiency of the sirocco fan, using two geometric
variables. Reducing the width of impeller could decrease the relative size of inactive zone and secondary flow.
Changing the position of cut-off had little influence on the efficiency. Thus an improvement of efficiency could be
achieved by reducing the width of impeller.
Keyword :
Sirocco fan; Sliding mesh; Width of impeller; Position of cut-off
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|