Effect of partial rotor-to-stator rub on shaft vibration Mohamed E. Eleshaky
The Journal of Mechanical Science and Technology, vol. 23, no. 1, pp.170-182, 2009
Abstract : The effect of partial rotor-to-stator rubbing is investigated both experimentally and analytically. It is found that due
to rubbing the measured vibration signal is distorted showing a flattened portion in the waveform. Spectral analysis
indicates that the synchronous component is generally attenuated as a result of rubbing-introduced-friction. It is also
indicated that light rubbing induced vibrations are characterized by harmonics at frequencies equal to 1x rev., 2x rev.,
and 3x rev. Whereas, severe rubbing is identified experimentally by a spectrum containing subharmonics at 1/3 and 2/3
of the rotational frequency. Because of the stiffening effect of rubbing on the rotor, the resonance frequency increases.
In general, the analytical results show good agreement with experimental data.
Keyword :
Rub; Partial Rubbing; Rotor; Rotordynamics; Vibrations
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|