CFD analysis of flow phenomena inside thermo vapor compressor influenced by operating conditions and converging duct angles Hyomin Jeong/Tony Utomo/M. Ji/Y. Lee/G. Lee
The Journal of Mechanical Science and Technology, vol. 23, no. 9, pp.2366-2375, 2009
Abstract : A thermo vapor compressor is simply a steam ejector employed in a multi effect desalination process. A greater understanding
of flow phenomena inside an ejector plays an important role in its performance improvement. In this paper,
CFD investigation has been carried out to study the flow structure inside a steam ejector. This research revealed the
influence of operating pressures and ejector geometries on the flow structure and the performance of a steam ejector.
The CFD results were verified with available experimental data. The angle of the converging duct as the geometry
parameter was varied as 0o, 0.5o, 1o, 2o, 3.5o and 4.5o. The best performance was obtained by the ejector with converging
duct angle of 1o.
Keyword :
Thermo vapor compressor; Steam ejector; Performance; CFD; Desalination
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|