Comparative analysis of the influence of labyrinth seal configuration on leakage behavior Tong Seop Kim, Kyu Sang Cha
The Journal of Mechanical Science and Technology, vol. 23, no. 10, pp.2830-2838, 2009
Abstract : This study analyzed the influence of configuration and clearance on the leakage behavior of labyrinth seals. Both
computational fluid dynamics (CFD) and an analytical tool were used to predict the leakage flow of two different
(straight and stepped) seal configurations with various clearances. The predicted results were compared with experimental
data. The CFD gives a better agreement with the experimental result than the analytical model on average. In
the straight seal, the dependence of the discharge coefficient on the clearance is considerable, while it is much smaller
in the stepped seal. The CFD captures the entire behavior sufficiently well, but the analytical model overpredicts the
clearance dependence in the stepped seal. The CFD also predicts well the influence of the flow direction on the leakage
flow. The advantage of the stepped seal over the straight seal becomes more evident as the clearance gets larger. As the
clearance becomes sufficiently small, the advantage of the stepped seal reduces.
Keyword :
Labyrinth seal; Straight; Stepped; Pressure ratio; Leakage; Number of teeth; Computational fluid dynamics
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|