Preliminary application of the draft code case for alloy 617 for a high temperature component Hyeong-Yeon Lee
The Journal of Mechanical Science and Technology, vol. 22, no. 5, pp.856-863, 2008
Abstract : The ASME draft Code Case for Alloy 617 was developed in the late 1980s for the design of very-high-temperature
gas cooled reactors. The draft Code Case was patterned after the ASME Code Section III Subsection NH and was intended
to cover Ni-Cr-Co-Mo Alloy 617 to 982¡ÆC (1800¡ÆF). But the draft Code Case is still in an incomplete status,
lacking necessary material properties and design data. In this study, a preliminary evaluation on the creep-fatigue damage
for a high temperature hot duct pipe structure has been carried out according to the draft Code Case. The evaluation
procedures and results according to the draft Code Case for Alloy 617 material were compared with those of the
ASME Subsection NH and RCC-MR for Alloy 800H material. It was shown that many data including material properties,
fatigue and creep data should be supplemented for the draft Code Case. However, when the evaluation results on
the creep-fatigue damage according to the draft Code Case, ASME-NH and RCC-MR were compared based on the
preliminary evaluation, it was shown that the Alloy 617 results from the draft Code Case tended to be more resistant to
the creep damage while less resistant to the fatigue damage than those from the ASME-NH and RCC-MR.
Keyword :
Creep-fatigue; High temperature design code; Alloy 617; Alloy 800H; Very high temperature reactor; Hot gas duct
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
JMST Editorial Office: #702 KSTC New Bldg, 22 7-gil, Teheran-ro, Gangnam-gu, Seoul 06130, Korea
TEL: +82-2-501-3605, E-mail: editorial@j-mst.org |
JMST Production Office: #702 KSTC New Bldg, 22 7-gil, Teheran-ro, Gangnam-gu, Seoul 06130, Korea
TEL: +82-2-501-6056, FAX: +82-2-501-3649, E-mail: editorial@j-mst.org |
|
|
|
|