Thermo-fluid characterization of flue gas flows through a packed bed Nat Vorayos
The Journal of Mechanical Science and Technology, vol. 22, no. 5, pp.973-980, 2008
Abstract : uniform
spheres was investigated in a custom-made experimental facility and reported in the present paper. Pressure drop,
temperature evolution and heat transfer characteristics were evaluated for a range of superficial velocities, Reynolds
numbers and bed geometries. Results revealed that increases in both superficial velocity and bed thickness caused a rise
in pressure drop across the packed bed in similar fashion to the Ergun equation but with different coefficients at low
Reynolds number between 60-300. The two constants were empirically determined to be 68.5 and 4.95. It was also
found that the packed bed affects axial temperature distribution from the incinerator chamber to stack. For the same
heating rate, higher temperature was achieved in the chamber with the packed bed, and peak temperature was reached
at a rate of 7-10% faster than that without the packed bed during the startup period.
The downstream side of the thicker bed appeared to have lower temperature than the thinner bed for the same axial
position, demonstrating less flue loss during the transient state. The incinerator chamber proved to have higher temperature
rising rate and reached higher maximum temperature with the presence of the packed bed.
Keyword :
Flue gas; Incinerator; Low reynolds number; Packed bed; Spheres
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
JMST Editorial Office: #702 KSTC New Bldg, 22 7-gil, Teheran-ro, Gangnam-gu, Seoul 06130, Korea
TEL: +82-2-501-3605, E-mail: editorial@j-mst.org |
JMST Production Office: #702 KSTC New Bldg, 22 7-gil, Teheran-ro, Gangnam-gu, Seoul 06130, Korea
TEL: +82-2-501-6056, FAX: +82-2-501-3649, E-mail: editorial@j-mst.org |
|
|
|
|